	<title>Centrifugal Pump Replacement Parts | Sanitary Pump Parts - Sanitary Fittings</title>
	<atom:link href="https://sanitaryfittings.us/product-category/sanitary-pumps/pump-replacement-parts/feed" rel="self" type="application/rss+xml" />
	<link>https://sanitaryfittings.us/product-category/sanitary-pumps/pump-replacement-parts</link>
	<description>Sanitary Fittings supplies stainless-steel products for the food, dairy, beverage, cosmetic, pharmaceutical, and industrial markets.</description>
	<lastBuildDate>Tue, 09 Sep 2025 00:03:12 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.3</generator>

<image>
	<url>https://sanitaryfittings.us/wp-content/uploads/2020/01/favicon-32x32.png</url>
	<title>Centrifugal Pump Replacement Parts | Sanitary Pump Parts - Sanitary Fittings</title>
	<link>https://sanitaryfittings.us/product-category/sanitary-pumps/pump-replacement-parts</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Impeller</title>
		<link>https://sanitaryfittings.us/product/pump-impeller-replacement</link>
		
		<dc:creator><![CDATA[John Zabkowicz]]></dc:creator>
		<pubDate>Tue, 08 Nov 2022 14:54:27 +0000</pubDate>
				<guid isPermaLink="false">https://sanitaryfittings.us/?post_type=product&#038;p=42623</guid>

					<description><![CDATA[<ul>
<li>Centrifugal Pump Impeller Replacement</li>
<li>316 Stainless Steel</li>
<li>Available in sizes: 100, 114, 216, 218, 328</li>
</ul>
<p>The post <a href="https://sanitaryfittings.us/product/pump-impeller-replacement">Impeller</a> appeared first on <a href="https://sanitaryfittings.us">Sanitary Fittings</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 id="SizeDim">Replacement Centrifugal Pump Impeller</h2>
<p>From time to time, centrifugal pump mechanical components need to be replaced. TOP-FLO® centrifugal pump replacement parts are specifically designed to fit in the pumps of not only TOP-FLO® pumps but those of major pump suppliers. These components are rugged and will provide the necessary sealing conditions under a wide range of conditions.</p>
<p>Learn more about choosing an impeller in our blog post, Pump Impellers: <a href="https://sanitaryfittings.us/pump-impellers-types-how-to-choose">3 Different Types and How to Choose the Right One</a>.</p>
<p>The post <a href="https://sanitaryfittings.us/product/pump-impeller-replacement">Impeller</a> appeared first on <a href="https://sanitaryfittings.us">Sanitary Fittings</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Centrifugal Pump Stub Shaft (MAR006)</title>
		<link>https://sanitaryfittings.us/product/centrifugal-pump-stub-shaft</link>
		
		<dc:creator><![CDATA[John Zabkowicz]]></dc:creator>
		<pubDate>Tue, 01 Nov 2022 13:32:01 +0000</pubDate>
				<guid isPermaLink="false">https://sanitaryfittings.us/?post_type=product&#038;p=42115</guid>

					<description><![CDATA[<ul>
<li>Available in sizes: 114, 216, 328</li>
<li><a href="https://dusouecxfowwg.cloudfront.net/wp-content/uploads/2021/06/TOP-FLO-Centrifugal-Pump-Manual.pdf" target="_blank" rel="noopener">Centrifugal Pump Manual</a></li>
</ul>
<p>The post <a href="https://sanitaryfittings.us/product/centrifugal-pump-stub-shaft">Centrifugal Pump Stub Shaft (MAR006)</a> appeared first on <a href="https://sanitaryfittings.us">Sanitary Fittings</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 id="SizeDim">Replacement Centrifugal Pump Stub Shaft</h2>
<p>From time to time, centrifugal pump mechanical components need to be replaced. TOP-FLO® centrifugal pump replacement parts are specifically designed to fit in the pumps of not only TOP-FLO® pumps but those of major pump suppliers. These components are rugged and will provide the necessary sealing conditions under a wide range of conditions.</p>
<div style="width:100%;display:flex;">
<img fetchpriority="high" decoding="async" src="https://sanitaryfittings.us/wp-content/uploads/2022/11/stub-shaft-diagram.png" alt="Stub Shaft Diagram" width="774" height="516" class="alignleft size-full wp-image-42134" srcset="https://sanitaryfittings.us/wp-content/uploads/2022/11/stub-shaft-diagram.png 774w, https://sanitaryfittings.us/wp-content/uploads/2022/11/stub-shaft-diagram-300x200.png 300w, https://sanitaryfittings.us/wp-content/uploads/2022/11/stub-shaft-diagram-768x512.png 768w, https://sanitaryfittings.us/wp-content/uploads/2022/11/stub-shaft-diagram-500x333.png 500w, https://sanitaryfittings.us/wp-content/uploads/2022/11/stub-shaft-diagram-272x182.png 272w" sizes="(max-width: 774px) 100vw, 774px" />
</div>
<h3>STUB SHAFT ADJUSTMENT</h3>
<ol>
<li>Push the stub-shaft/impeller assembly<br />
toward the motor until the impeller strikes<br />
the front face of the backplate.</li>
<li>Move the stub-shaft away from the<br />
motor shaft to allow 1/16-inch maximum<br />
clearance between the rear face of the<br />
impeller and the front (inside) face of the<br />
backplate. (See Figure 22)</li>
<li>Tighten the two set screws on the stubshaft.</li>
<li>Remove the impeller retainer pin, impeller,and the backplate.</li>
<li>Slide the deflector (large diameter end<br />
first) onto the shaft until it seats in the<br />
shaft groove. (Figure 23)</li>
</ol>
<p><i>NOTE: If the deflector cannot be forced on with the fingers, use a blunt tool to tap it</i></p>
<table style="width:400px;margin-top:20px;">
<tr>
<th style="background:#f78e1e !important;border:1px solid black;color:#fff;">CAUTION</th>
</tr>
<tr>
<td style="border:1px solid black;">The stub shaft has four sharp diagonal<br />
grooves in the end. Wear gloves to<br />
prevent injuries to hands</td>
</tr>
</table>
<p>The post <a href="https://sanitaryfittings.us/product/centrifugal-pump-stub-shaft">Centrifugal Pump Stub Shaft (MAR006)</a> appeared first on <a href="https://sanitaryfittings.us">Sanitary Fittings</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Castellated Nut (Acme Thread)</title>
		<link>https://sanitaryfittings.us/product/castellated-nut</link>
		
		<dc:creator><![CDATA[John Zabkowicz]]></dc:creator>
		<pubDate>Sun, 30 Oct 2022 20:21:19 +0000</pubDate>
				<guid isPermaLink="false">https://sanitaryfittings.us/?post_type=product&#038;p=42017</guid>

					<description><![CDATA[<ul>
<li>Centrifugal Pump Castellated Nut Replacement</li>
<li>316 Stainless Steel</li>
<li>Available in sizes: 114, 216, 218</li>
</ul>
<p>The post <a href="https://sanitaryfittings.us/product/castellated-nut">Castellated Nut (Acme Thread)</a> appeared first on <a href="https://sanitaryfittings.us">Sanitary Fittings</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 id="SizeDim">Replacement Centrifugal Pump Castellated Nut (Acme Thread) for use with Stub Shaft</h2>
<p>From time to time, centrifugal pump mechanical components need to be replaced. TOP-FLO® centrifugal pump replacement parts are specifically designed to fit in the pumps of not only TOP-FLO® pumps but those of major pump suppliers. These components are rugged and will provide the necessary sealing conditions under a wide range of conditions.</p>
<p>The post <a href="https://sanitaryfittings.us/product/castellated-nut">Castellated Nut (Acme Thread)</a> appeared first on <a href="https://sanitaryfittings.us">Sanitary Fittings</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Follower</title>
		<link>https://sanitaryfittings.us/product/follower</link>
		
		<dc:creator><![CDATA[John Zabkowicz]]></dc:creator>
		<pubDate>Fri, 28 Oct 2022 21:52:16 +0000</pubDate>
				<guid isPermaLink="false">https://sanitaryfittings.us/?post_type=product&#038;p=41980</guid>

					<description><![CDATA[<ul>
<li>Centrifugal Pump Follower Replacement</li>
<li>316 Stainless Steel</li>
<li>Available in sizes: 114, 216, 328</li>
</ul>
<p>The post <a href="https://sanitaryfittings.us/product/follower">Follower</a> appeared first on <a href="https://sanitaryfittings.us">Sanitary Fittings</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 id="SizeDim">Replacement Centrifugal Pump Follower</h2>
<p>From time to time, centrifugal pump mechanical components need to be replaced. TOP-FLO® centrifugal pump replacement parts are specifically designed to fit in the pumps of not only TOP-FLO® pumps but those of major pump suppliers. These components are rugged and will provide the necessary sealing conditions under a wide range of conditions.</p>
<p>The post <a href="https://sanitaryfittings.us/product/follower">Follower</a> appeared first on <a href="https://sanitaryfittings.us">Sanitary Fittings</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>83C Stuffing Box</title>
		<link>https://sanitaryfittings.us/product/83c-stuffing-box</link>
		
		<dc:creator><![CDATA[John Zabkowicz]]></dc:creator>
		<pubDate>Fri, 28 Oct 2022 21:41:50 +0000</pubDate>
				<guid isPermaLink="false">https://sanitaryfittings.us/?post_type=product&#038;p=41972</guid>

					<description><![CDATA[<ul>
<li>83C Stuffing Box Replacement</li>
<li>316 Stainless Steel</li>
<li>Available in sizes: 114, 216, 328</li>
</ul>
<p>The post <a href="https://sanitaryfittings.us/product/83c-stuffing-box">83C Stuffing Box</a> appeared first on <a href="https://sanitaryfittings.us">Sanitary Fittings</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 id="SizeDim">Replacement Centrifugal Pump 83C Stuffing Box</h2>
<p>From time to time, centrifugal pump mechanical components need to be replaced. TOP-FLO® centrifugal pump replacement parts are specifically designed to fit in the pumps of not only TOP-FLO® pumps but those of major pump suppliers. These components are rugged and will provide the necessary sealing conditions under a wide range of conditions.</p>
<p>The post <a href="https://sanitaryfittings.us/product/83c-stuffing-box">83C Stuffing Box</a> appeared first on <a href="https://sanitaryfittings.us">Sanitary Fittings</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Drive Collar (MAR00)</title>
		<link>https://sanitaryfittings.us/product/drive-collar</link>
		
		<dc:creator><![CDATA[John Zabkowicz]]></dc:creator>
		<pubDate>Thu, 13 Oct 2022 01:02:58 +0000</pubDate>
				<guid isPermaLink="false">https://sanitaryfittings.us/?post_type=product&#038;p=40903</guid>

					<description><![CDATA[<ul>
<li>"D" / "E" Series Centrifugal Pump Drive Collar</li>
<li>Available in sizes: 114, 216, 328</li>
<li><a href="https://dusouecxfowwg.cloudfront.net/wp-content/uploads/2021/06/TOP-FLO-Centrifugal-Pump-Manual.pdf">Centrifugal Pump Manual</a></li>
</ul>
<p>The post <a href="https://sanitaryfittings.us/product/drive-collar">Drive Collar (MAR00)</a> appeared first on <a href="https://sanitaryfittings.us">Sanitary Fittings</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 id="SizeDim">Replacement Centrifugal Pump Drive Collar</h2>
<p>From time to time, centrifugal pump mechanical components need to be replaced. TOP-FLO® centrifugal pump replacement parts are specifically designed to fit in the pumps of not only TOP-FLO® pumps but those of major pump suppliers. These components are rugged and will provide the necessary sealing conditions under a wide range of conditions.</p>
<div style="display: flex; width: 100%;"><img decoding="async" class="alignleft size-full wp-image-42009" src="https://sanitaryfittings.us/wp-content/uploads/2022/10/drive-collar-highlight.png" alt="Centrifugal Pump Drive Collar Highlight" width="384" height="200" srcset="https://sanitaryfittings.us/wp-content/uploads/2022/10/drive-collar-highlight.png 384w, https://sanitaryfittings.us/wp-content/uploads/2022/10/drive-collar-highlight-300x156.png 300w" sizes="(max-width: 384px) 100vw, 384px" /></div>
<h3>Drive Collar Adjustment</h3>
<p>(Models TF-C114 through TF-C328)</p>
<ol>
<li>Slide the seal drive collar onto the stub<br />
shaft as shown in Figure 24.<br />
Use the “A” dimension in the SEAL CHART<br />
to properly locate the drive collar on the<br />
stub shaft. Tighten the set screws to<br />
secure in place.<br />
<em>NOTE: TF-C100 pump does not require drive<br />
collar.</em></li>
<li>Assemble the spring, seal cup, o-ring, and<br />
carbon seal, and install as a unit. Make<br />
sure the slot in the seal cup aligns with<br />
the pin on the shaft. (Figure 25) Gentle<br />
pressure on the o-ring will overcome<br />
resistance on the shaft.<br />
NOTE: Do not lubricate seals with any<br />
type of oil or grease, the seal faces will be<br />
lubricated by the product being pumped.</li>
<li>Assemble the gasket to the backplate.<br />
Install the backplate on the adapter. Make<br />
sure the seal cup slot is engaged with the<br />
pin on the drive collar. (Figure 25)</li>
<li>Rotate the backplate until the backplate<br />
pins engage the adapter pins. (Figure 25)</li>
<li>Rotate the shaft until the pin hole in the<br />
end is in a horizontal position. Insert the<br />
impeller pin, center it in the shaft end, and<br />
slide the impeller on the shaft.<br />
Hold the impeller tight against the stub<br />
shaft and rotate the shaft one-fourth turn<br />
until the impeller pin drops and secures the<br />
impeller. (Figure 26)</li>
<li>Place the casing over the impeller/<br />
backplate, close and tighten the clamp.<br />
(Figure 27)</li>
<li>Assemble the cascade water fitting, if<br />
included. Install the seal guard and tighten<br />
in place. Assemble the suction line and the<br />
discharge line to the casing.</li>
</ol>
<p><em>NOTE: Check for strain or misalignment<br />
of piping to the casing. Re-adjust the<br />
casing ports and/or entire motor leveling as<br />
necessary.</em></p>
<p>The post <a href="https://sanitaryfittings.us/product/drive-collar">Drive Collar (MAR00)</a> appeared first on <a href="https://sanitaryfittings.us">Sanitary Fittings</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>